MEMO POWER PLUS 10KVA
The Memopower Plus Parallel Redundancy on-line series, featured with N+X parallel redundancy, DSP-controlled technology, high input & output power factors, superior input voltage window for energy saving, estimated remaining time, ECO mode,, is an ideal solution to your server, bank, industrial equipment, IT equipment, communication system or other networking equipment, which is demanding for a thorough protection.
Features
-N+X Parallel Redundancy
-Online Double Conversion with DSP Control
-Graphic LCD Display with Multifunction Parameter Settings
-Unity Input Power Factor with Low Input Current Distortion
-High Output Power Factor at 0.9PF
-Low Input Current Distortion
-Green Concept design with Superior Input Voltage Window for Energy Saving
-Support Generator Input
-Estimated Remaining Time displayed on the LCD.
-Support Economic(ECO) Operation Mode
-Settable Battery Voltage
-Automatic Battery Test Available
-Load -controlled fan
-Matching Battery Pack with Powerful Charger Built-in
-Common Battery When UPS in Parallel Mode
-Versatile Communication Interfaces Available
-Cold Start
-Communication Software
-Optional Centralized monitor function
-Settable Charge Current
Input
Phase - Single phase &Ground
Rated Voltage - 220/230/240VAC
Voltage Range - 120VAC-276VAC
Frequency Range - 40Hz-70Hz
Power Factor - ≥0.99
Current THOi - ≤5%(100% nonlinear load)
Bypass Voltage Range - Max.voltage:+15%(optional+5%, +10%, +25%)
- Min. voltage: -45% (optional -20%, -30%)
- Frequency protection range: :±10%
ECO Range - same as the bypass
Generator Input - support
Output
Phase - Single phase &Ground
Rated Voltage - 220/230/240VAC
Power Factor - 0.9
Voltage Regulation - ±2%
Frequency - Utility Mode - ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency(optional)
- Battery Mode - (50±0.2)Hz
Crest Factor - 3:1
THD - ≤2% withlinear load, ≤5% with non linear load
Waveform - pure sinewave
Battery
Voltage - Standard:192Vdc; OptionalVoltage: 216/240Vdc
Capacity - 16 x 12V/9AH
Backup Time - Full load ≥2min(Standard),Long time unit depends on the capacity of external batteries
Estimated remaining time displayed on the LCD
Recharge Time to 90% - 8 to 10 hours (standard)
Charging Current - 1A
Transfer Time
Protection - overload - AC mode - Load≤110%:last 3min, ≤125%: last 30S, ≤150%:last 1S, ≥150% shut down UPS immediately
- Batt. mode - Load≤110%: last 30S. ≤125%: last 1S, ≤150%:last 200ms, ≥150% shut down UPS immediately
- Bypass mode - 60A (input breaker)
Physical
Dimension - 250x 655x 590
Weight - 85 Kg