Features:
- fully dielectric
- resistant to electromagnetic interferences
- resistant to longitudinal water penetration
- can be installed in the proximity to electric installation
- easy to install
Applications:
Cables are designated for transmission of digital and analogue signals within the whole optical bandwidth. They are prepared for making fast connection between optoelectronics devices, laying in cable ducts, use in places with high risk of rodents attack.

Cable construction: 1. Central element non-metallic 2. Optical fibres 3. Loose tube 4. Filler 5. Waterblocking tape 6. Reinforcement (glass yarn) 7. Outer sheath 8. Ripcord
|
| Construction |
Properties ( Type / Material / Dimension ) |
| Fibres |
ITU-T G.652D |
| Identification of fibers |
Comply to IEC 60304: Red; Green, Blue, White, Violet, Orange, Grey, Yellow, Brown, Pink, Black, Turquoise |
|
Identification of tubes/ elements 6 to 12 elements Above 12 - elements - two layers 18 elements (6+12) 24 elements (9+15)
|
First tube - red, second tube - blue, other tube - natural, filler (when needed) - black for each of the layers of colors as above
|
| Central support member |
Straight rod |
Fibre Reinforced Plastic |
Φ1,8 or 2,5 mm |
| PE oversheath on central support member |
Black
|
HDPE |
Φ 3,0 mm for 8 elements cable Φ 5,3 mm for 12 elements cable Φ 3,5 mm for 9+15 elements cable |
| Secondary coating |
lloose tube - thermoplastic material, containing 2, 4, 6 or 12 fibres, |
PBT |
Φ 1,8 mm approx. |
| Filling of the tube |
gel |
Thixotropic gel |
|
| Interstitial waterblocking |
Dry sealed |
Swelling tape |
thickness: 0,20mm (approx.) |
| Reinforcement |
Dielectric yarn |
Glass yarns |
|
| Outer sheath |
Black |
extruded HDPE polymer density 3 0,945 g/cm3
|
thickness: minimum spot average
|
1,3mm 1,5mm
|
| Attenuation @1310nm |
≤ 0,4 dB/km *)
|
| Attenuation @1550nm |
≤ 0,25 dB/km *)
|
|
*) Max attenuation for SMF in cable - other parameters of the fiber according to the attached specifications
|
|
| |
| Construction characteristics |
Properties |
| Water penetration |
IEC 60794-1-2-F5B |
Sample 1m, water head 1m, 24 hours |
| Temperature range |
- transport/storage -40/+70 °C - installation -15/+60 °C - operation -40/+70 °C
|
|
Outer diameter of tube (mm)
|
1,8 mm |
|
No. of elements in a cable (tubes/filers)
|
6 |
| Cable Outer diameter |
9,5 mm |
|
Cable weigth
|
75 kg/km |
| Mechanical properties |
| Max. tensile load during installation |
2700 N |
| Max. tensile load during operation |
1350 N |
| Min. bending radius during installation |
145 mm |
|
|