High power density
LCD supports Rack/Tower convertible design
N+X parallel redundancy, support a maximum of 4 units in parallel
Online double conversion with full digital control
Optimization battery group, the quantity of battery:16/18/20pcs (Settable)
Wide input voltage range:110~286Vac
Wide input frequency range
Generator compatible
ECO mode operation for energy saving
Self-testing when UPS startup
communication interfaces: RS232/USB/EPO(Relay card/SNMP card optional)
Parallel kit default
Maximum charging current up to 10A
Cold start
Intelligent fan speed regulation
Multiple protection functions: short-circuit, overload, overheat, battery overcharge and over-discharge, output low voltage and fan fault alarm
| MODEL | MP RT 6k | ||||
| Capacity | 6000VA/ 5400W | ||||
| INPUT | |||||
| Nominal voltage | 208/220/230/240Vac | ||||
| Input voltage range | 110~286Vac | ||||
| Frequency range | 40~70Hz (50/60Hz Auto-Sensing) | ||||
| Power factor | ≥0.99 | ||||
| Max.voltage:220V:+25% (Optional+10%,+15%,+20%) 230V:+20% (Optional+10%,+15%,+20%) | |||||
| Bypass voltage range | 240V:+15% (Optional+10%) | ||||
| Min.voltage:-45% (Optional-20%,-30%) | |||||
| OUTPUT | |||||
| Output voltage | 208/220/230/240Vac | ||||
| Power factor | 0.9 | ||||
| Voltage regulation | ±1% | ||||
| Output frequency | Line Mode | ±1%/±2%±/±4%/±5%/±10% of the rated frequency (Optional) | |||
| Bat. Mode | (50/60±0.1%)Hz | ||||
| Crest factor | 3:01 | ||||
| Harmonic distortion (THDv) | ≤2% Linear load | ||||
| ≤5% Non linear load | |||||
| Transfer time | AC mode to Bat.Mode | 0ms | |||
| Inverter to Bypass | 0ms | ||||
| Output waveform | Pure Sinewave | ||||
| Overload | Line Mode | Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min; >150% turn to bypass mode immediately | |||
| Bypass Mode | 40A (Breaker) | ||||
| Efficiency | 94% | ||||
| BATTERY | |||||
| Battery voltage | ±96/±108/±120Vdc (Adjustable) | ||||
| Capacity (Standard unit) | BATTERY PACK 20*7Ah/12V - not included / seperate unit | ||||
| Typical recharging time | 6~8 hours (to 90% of full capacity) | ||||
| Charging current | 1A (Standard unit); Long run unit Max.current 10A (Charging current can be set according to battery capacity) | ||||
| INDICATORS | |||||
| LED display | Line mode,Bat.mode,ECO mode,Bypass mode,Battery low voltage,Overload & UPS fault | ||||
| LCD display | Input voltage,Input frequency,Output voltage,Output frequency,Load percentage, | ||||
| Battery voltage,Inner temperature& Remaining battery backup time | |||||
| ALARM | |||||
| Battery mode | Beeping every 4 seconds | ||||
| Battery low | Beeping every second | ||||
| Overload | Beeping twice every second | ||||
| Fault | Continously beeping | ||||
| PHYSICAL | |||||
| Dimension W x D×H (mm) | 440 x 625 x 86.5 | ||||
| Net weight (kg) | 16 | ||||
| ENVIRONMENT | |||||
| Operating temperature | 0℃~40℃ | ||||
| Storage temperature | -25℃~55℃ | ||||
| Humidity range | 20~95%RH @ 0~40℃ (Non condensing) | ||||
| Altitude | <1500m,derating required when>1500m | ||||
| Noise level | <55db at 1 Meter | ||||
| STANDARDS | |||||
| Safety | IEC/EN62040-1,IEC/EN62477-1 | ||||
| EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 | ||||