GF series off-grid solar power inverter adopts Digital Intelligent Control and complete high frequency conversion topology, with high reliability and strong anti-interference. The rating input voltage is 24V/48V and rated power rating is 500W to 10KW. It is widely used in the solar power supply system such as communications, transportation, islands, border, rural, pastoral areas and so on.
Multi-setting: PV priority mode or AC priority mode. Choose the charging current based on the configured capacity of the battery. High reliability: Double CPU digital control: Independent MPPT (Maximum Power Point Tracking) control microprocessor system Independent inverter microprocessor control system Isolated and pure sine wave technique: LCD+LED display mode: wide input range high-speed synchronous conversion The system can track the Mains phase automatically, and make sure the inverter output voltage is the completely same as the Mains voltage Friendly alarm system Unattended and intelligent monitoring:It can communicate with the PC by RS232 or USB interface,It also can realize remote monitoring, testing and regular shutdown/ starting-up operation by SNMP network system. Online protection function Intelligent No-load auto shutdown technology (optional)
|
| Specifications |
| Power Capacity |
3KW |
| Batteryvoltage |
192Vdc |
| Working mode |
PV Priority/ AC Priority optional
|
| PV |
Input voltage range |
192-400Vdc
|
| Max. charge current |
10-40A /60A (settable)
|
|
PV panels configuration (Suggestion)(Imp≤rated current )
|
10-40A /60A
|
|
Max .efficiency
|
≥ 98 % |
| Display |
Panel indicator light |
LCD + LED display |
AC mode (settable) |
Input voltage range |
175Vac- 275Vac
|
| Input Frequency range |
40-70Hz(autoly transfer to battery mode beyond this range)
|
| Output voltage range |
220Vac± 5%
|
|
Input power factor
|
≥80%
|
| Max. efficiency |
88%(inverter on)
|
|
Over load
|
110% transfer to bypass in 255s,120% go to bypass in 60s |
|
Max. charging current
|
12A |
| Short circuit protection |
Electronic limited current output or turn bypass, air breaker protection
|
| Inverter output |
Inverter output voltage |
220Vac± 5%
|
| Output frequency |
50 Hz / 60Hz ± 1% Frequency self –adjusted |
| Output power factor |
≥0.8
|
| Wave form distortion |
≤ 5% Linear load
|
| PV-AC transfer time |
≤ 0Ms
|
| Max. efficiency |
92%
|
| Inverter overload |
110% transfer to bypass, in 255s or shut down,120% go to bypass or shut down in 60s
|
|
Eco mode (optional)
|
When Load < 5%, system will turns to bypass power supply (utility) in 1min |
| Short circuit |
Electronic limited current output, turn the bypass or system to be automatic shutdown |
| Alarm |
AC fails
|
4s once ,noise reduction after 40s
|
|
Batterylow voltage
|
0.2S Once
|
| Overload |
1 / 1S
|
| Communication interface(Optional) |
RS232 / USB /RS485/ SNMP
|
| Others |
Connection
|
Terminal blocks |
| Surge protection |
Optional |
| Magnetic Compatibility |
Accord with EN62040-2:2006;EA61000-3-2:2006; EA61000-3-3:2008
|
| IP class |
IP20 |
| Ambient temperature |
0℃ ~40℃ |
| Ambient humidity |
10% ~90%(Non Condensed) |
| Noise |
≤ 50dB |
Dimension D*W*H(MM) |
560*265*725
|
| Weight(kg) |
60 |
| Packing weight(kg) |
68 |
|