30kVA Triphase Voltage Stabilizer with servomotor

Braun Group - ES-SVC30KVA380

Triphase Voltage Stabilizer with servomotor. Max. power 30kVA. Ui: 276VAC-4350VAC; Uo: 380VAC; <3% precision, manual bypass

More images:
ES-SVC380ES-SVC380
This product is no longer available
*) VAT not included
Availability :
not available

Main Features:

+ Three phase compensation servo motor technology
+ Wide AC input voltage range 276-450V
+ 100% unbalanced loading capability between three phases
+ Digital display for voltage and current
+ Isolated manual bypass switch
+ Full protections such as over voltage, under voltage, overload, overheat, etc
+ Selectable 6s/180s output delay
+ Optional surge/spike protection (replaceable SPD)
+ Optional output isolation transformer
+ Optional RS232/RS485
Typical Applications:

+ Multi-color printing machines
+ Air compressors
+ CNC machines
+ Punching machines
+ Laser cutting machines
+ Welding machines

        Specifications:

 

INPUT
Rated Input Voltage 380V (400V/415V Optional)
InputVoltageRange 276-450V
Input Frequency 45-65Hz
Power Factor 0.98

 

OUTPUT
Rated Output Voltage 380V (400V/415V Optional)
Output Precision ±3% (±1% Optional)
Response Time <1s, against 10% variation of input voltage
Efficiency >96%

 

DIGITAL DISPLAY
Input Voltage Line Voltage: AB, BC, CA          Phase Voltage: A, B, C
Output Voltage Line Voltage: AB, BC, CA          Phase Voltage: A, B, C
Output Current Phase Current: A, B, C

 

PROTECTION
Output Under Voltage Output cutoff by contactor + "L" in display + Buzzer beeping
Output Over Voltage Output cutoff by contactor + "H" in display + Buzzer beeping
Overload Output cutoff by contactor + "F" in display + Buzzer beeping
Overheat Output cutoff by contactor + "C" in display + Buzzer beeping
Phase Failure Output cutoff by contactor + Buzzer beeping
Wrong Phase Sequence Can't switch on regulator
Short Circuit Input cutoff by air breaker
Bypass Isolated Manual Bypass Switch (Automatic Bypass Optional)
Output Delay Time 6s/180s Selectable
Surge Spike Optional, Replaceable SPD
RS232/RS485 Optional

 

SAFETY
Insulation Voltage 2,000V / 60s
Insulation Resistance >5MΩ
Creepage Distance >8mm
Grounding Resistance <0.1mΩ
Insulation Class of Coil Class F (155?)
Cooling Mode Cooling Fan
IP Level IP20
Audible Noise  

 

OPERATING CONDITIONS
Operating Temperature -5°C - +45°C
Operating Humidity 10%-90%, non-condesing
Operating Altitude <1,000m

 

MODEL AVAILABLE:
Model No. 10KVA 15KVA 20KVA 30KVA 45KVA 60KVA 80KVA 100KVA
Capacity 10kVA/6kW 15kVA/9kW 20kVA/12kW 30kVA/18kW 45kVA/36kW 60kVA/48kW 80kVA/64kW 100kVA/80kW
Machine Size D520 x W460 x H830 mm D600 x W520 x H1080 mm D600 x W570 x H1080 mm
N.W. 70kgs          78kgs        100kgs         108kgs 175kgs              190kgs 210kgs               235kgs
Packing Size D530 x W470 x H850 mm D610 x W530 x H1200 mm D610 x W580 x H1200 mm
G.W. 80kgs          88kgs         110kgs        118kgs 190kgs              205kgs 228kgs               253kgs 



*Nota: Fotografiile sunt cu caracter general si nu creeaza obligatii contractuale.
Produsul poate arata diferit in realitate.
Specificatiile pot fi schimbat fara preaviz.

We use cookies to improve your site experience, to analyze website traffic and audience. By continuing to browse our website, you acknowledge your acceptance of cookie usage under the Cookie Usage Policy, agree to the Personal Data Processing Policy, and have noted the Personal Information Processing Note. Accept