Osciloscop analogic Atten AT7340S

Atten - AT7340S

Osciloscop analogic

Osciloscop analogic 40MHz

Pret: 546,00 EURO
*) Pretul nu contine TVA
Disponibilitate : Sunati

 

 

Atten AT7340S Analog Oscilloscope - 40MHz
 
Features
 • 20MHz Dual Channels
 • High Sensitivity 1mV/DIV
 • Z Axis Input
 • CH1 Output
 • ALT Triggering Function.Two independentsignalssimultaneous observation
 • Triggering Level Loch Function,Automatic Synchronize Function
 • Cursor Readout Function,Measure ΔV,ΔT,1/ΔT
 • High luminance,internal graticule Toshiba CRT
 • Pulse encoder switch
 • Pulse encoder switch
 • Adjustable cursor function,Easy to operator 
 • Visible coordinate sensitivity to 10V~20V/DIV
 
Specifications
1) Vertical System
Sensitivity 5mV~5V/div,10 steps in 1-2-5 sequence
Sensitivity Accuracy ≤3%(x5 MAG: ≤5%)Vernier vertical Sensitivity; Continuously variable to 1/2.5 or less of panel-indicated value Frequency
Bandwidth DC~40MHz(x5 MAG:DC~15MHz) AC Coupling:Low limit frequency 10Hz.(With reference to 100Kz,8DIV. Frequency response with-3dB)
Rise Time Approx:9.5ns(x5 MAG:25ns)
Input Impedance Approx:1MΩ/25pF
Square wave characteristics: Overshoot: ≤5%(At 10mV/div range)
Other distortions and other ranges:5% added to the above value.
DC Balance Shift 5mV~5V/div:±0.5DIV, 1mV~2mV/DIV ±2.0DIV
Linearity <±0.1DIV of amplitude change when waveform of 2DIV at graticule center is moved vertically.
Vertical system: CH1: Channel 1
       CH2: Channel2
       DUAL: Channel 1 and Channel 2
       ADD: Addition of Channel 1 and Channel 2
Chopping repetition Frequency Approx.. 250KHz
Input Coupling AC , GND , DC
Maxmum Input Voltage 300Vpeak(AC: frequency 1kHz or lower)
Common mode rejection ratio:50: 1 or better at 50KHz sinusoidal wave(When sensitivities of CH1 and CH2 are set equally)
Isolation between channels(At 5mv/DIV range) >1000: 1 at 50kHz ; >30: 1 at 40MHz
2) Horizontal System
Sweep time: 0.2uSec~0.5Sec/DIV, 20steps in 1-2-5 sequence;
Sweep time accuracy: ±3%
Vernier sweep time control: ≤1/2.5 of panel-indicated value;
Sweep magnification: 10 times;
x10MAG sweep time accuracy: ±5%(20nsec ~50nsec are uncalibrated)
Linearity: ±3%, x10MAG ±5%(20nsec ~50nsec are uncalibrated)
Position shift caused by x10MAG: within 2DIV. at CRT screen center
X-Y MODE: Frequency bandwidth: DC to atleast 500kHz;
X-Y phase difference: ≤30 at DC~5kHz
Sensitivity: Same as vertical axis. (X-axis: CH1 input signal; Y-axis:CH2 input signal)
3) Z Axis
Sensibility: 5Vp-p (Positive-going signal decreases intensity)
Frequency bandwidth: DC~2MHz
Input resistance : Apporx. 47kΩ
Maximum input voltage: 3V (DC+AC peak, AC frequency ≤1kHz)
4) CALIBRATION VOLTAGE
Waveform: Positive-going square wave;
Frequency: Approx. 1kHz;
Duty ratio: Within 48: 52;
Output voltage: 2Vp-p ±2%; Output impedance: Approx. 1kΩ
5) CRT
Type: 6inch rectangular type, internal graticule;
Phosphor: P31
Acceleration voltage: Approx. 2kV
Effective screen size: 8x10DIV(1 DIV=10mm(0.39in))
Graticule: Internal
Trace rotation: provided
6) TRIGGERING
Triggering source: CH1, CH2, LINE, EXT
Coupling: AC: 20Hz to full bandwidth
Slope: +/-
Sensitivity: 20MHz~40MHz: 0.5DIV
TRIG-ALT: 2DIV, EXT: 200mV
20 MHz ~40MHz: 2.0DIV
TRIG-ALT: 3DIV, EXT: 800mV;
TV: Sync pulse more than 1DIV (EXT: 1V)
Triggering modes: AUTO; NORM; TV-V; TV-H; (Both TV-V and TV-H synchronize only when the synchronizing signal is negative)
EXT triggering signal input:
Input impedance: Approx: 1MΩ/approx. 25p
Max. input voltage: 300V(DC+AC peak), AC: Frequency not higher than 1kHz
7) Power requirement
Voltage: Fixed AC220V±10% or 110/220V±10% selectable
Frequency:50/60Hz
Power conseumption: Approx.40VA,35W(max)
8) Operating Ambient
Indoor,2000m elevation
Ambient temperature:10°C~35°C
Max operating range:0°C~40°C
Humidity:85% RH ,dry
Size:310x150x455(mm)
Weight:approx.8Kg
Storage temperature:-10°C~70°C
 
* Specificatiile pot fi schimbate fara preaviz