E1 to V.35 Interface Converter, 75/120ohm

E1 to V.35 Interface Converter, 75/120ohm

Acest produs nu mai este disponibil!

F4-51 E1/10Base-T Converter
 
   Overview
   The F4-56 gives the interface conversion between G.703 E1 and V.35. Provides an economical digital access solution for E1 and Fractional E1 network services. With a adapter cable, the device can link to other DTE Device, such as a router, at data rates of 64Kbps to 2048Kbps. User data is placed into the E1 frame, using only the required number of timeslots. Timeslot assignment is accomplished according to the Data Port speed and manual setting of DIPswitches. The main E1 link may be clocked from the recovered receive clock, from the Data Port clock, or from an internal oscillator. F4-56 is widely used in communication network, both in WAN and LAN field.
 
Features
 •  Interface conversion between E1 and V.35
 •  Access to E1 & Fractional E1 services  
•  E1 port: 75ohm & 120ohm impedance optional, use BNC and RJ45 port respectively
 •  Data rate: DIP selectable, Nx64Kbps  2048Kbps
 •  Full transparent signal conversion under unframed mode
 •  Clock regeneration from incoming HDB3 Data
 •  Support local & remote loop test
 •  Alarm LED: LOS LOF AIS RAL (Remote Syn. Loss)
 •  DB25 connector for V.35, with DCE mode
 •  Multiple clock selection: internal clock, V.35 recovery clock and E1 recovery clock at your selection
 •  Internal power supply, 220V AC and 48V DC optional
 •  Standalone and Chassis optional
 
Specifications
    E1 port
   •  Framing: Unframed/Framed, PCM31/PCM30, CRC4 ON/OFF
   •  Bit Rate: 2.048Mbps
   •  Line Code: HDB3
   •  Line Impedance: 75 ohm & 120 ohm
   •  Compatible with ITU G.703, G.704
   •  Jitter Performance: compatible with G.742 and G.823
   •  Interface Connectors: BNC (x2) connectors for line impedance 75ohm, RJ45 connector for line impedance 120ohm
Table1: 120ohm E1 Port's Definition
  Pin     3     4     5     6     2,7     Other  
  Func.     TX+     TX-     RX-     RX+     GND     N.A.  

    V.35 port
   • Data Rate: 2048Kbps(unframed) or nx64Kbps, where n equal 1 to 31 in PCM31 (CCS) and n equal to 30 in PCM30 (CAS)
   • Line code: NRZ
   • Connector: 25pin, D-type Female, with an adapter cable of DB25 male to M34 Female
   • Work Mode: DCE Modes
   • Clock: Recovery form E1; User Data port; Internal OSC

    General
   • Operating temperature: 0-50
   • Power Supply: -48VDC or 220VAC 20%
   • Dimension:
      • Standalone: 270mm(Width)*137mm(Depth)*40mm(Height)
      • Module (Card): 220mm(Depth) * 146mm(Height)
      • Chassis: 440mm(Width) * 250mm(Depth) * 178mm(Height)
 
Appearance
    Front Panel of standalone
    Back Panel of standalone

    Front Panel of Chassis

    Back Panel of Chassis

    Front Panel of Module

    Layout of Module
 
LED Status Description
Table 2 LED Status Description
 Indicator   Color   Status   Description 
 PWR   Green   ON   Power Supply OK 
 TX   Yellow   TX   User Data Port is Receiving data (Data is from DTE to DCE) 
 RX   Yellow   ON   User Data Port is transferring data (Data is from DCE to DTE) 
 RAL   RED   ON   Remote Device Frame Syn Loss 
 AIS   Red   ON   All 1's Alarm 
 LOS   Red   ON   E1 Signal Loss 
 LOF   RED   ON   Local Device Frame Syn Loss 
 RLP   Green   ON   Remote Loop Back Successful 
 LLP   Green   ON   Local Loop Back Successful 
 
DIP Switch Setting Tables
    E1 line impedance selection
    Table 3: SW1/SET1 75/120ohm Selection Switch
  Switch Position     75Oohms     120ohms  
  1     OFF     ON  
  2     ON     OFF  
  3     ON     OFF  
  4     ON     OFF  
Note: SW1 is for module, SET1 is for standalone device

    Functional setting
    Table 4 SET2/SW2 functional setting
           Pos    1       2       3       4       5       6       7       8   
Mea.
   ON   Reversed 
 Must be
  OFF
 Slave   Work   Reversed 
 Must be
  OFF.
 No CRC Check   PCM30   Clock mode,
 see table 5 for 
 detail
   OFF   Master   Remote Loop Back   CRC Check   PCM31 
   Factory
   Default 
 OFF   OFF   ON   OFF   OFF   OFF   ON   ON 
    Note :
 1. SW2 is for module; SET2 is for standalone device.
 2. Set both side in master mode under normal condition.
 3. For remote controlling, such as remote loop back test and remote bandwidth setting, set the local side in master mode, remote side in slave mode.

Table 5 Clock mode selection
   Clock Mode       Position 7 and 8 of SET2/SW2   
   Pos. 7       Pos. 8   
 Internal OSC.     OFF       OFF   
 Recovery from E1     ON       ON   
 V.35 DTE Clock     OFF       ON   
 Reserved     ON       OFF   

Table 6: SET3/SW3 Functional setting
  Position     1     2     3     4     5     6     7     8  
  ON     Bandwidth selection, see table 7 for detail. Meaningful only when Pos.8 is ON.   RCK Normal     TCK Normal     Framed  
  OFF     RCK Reverse     TCK Reverse     Unframed  
  Factory Default     OFF     OFF     OFF     OFF     OFF     ON     ON     OFF  
  Note: SW3 is for module; SET3 is for standalone device.

Table 7: Bandwidth setting
  SET3/SW3 Pos.1 Pos.5 setting     Bandwidth  
  1     2     3     4     5  
  ON     ON     ON     ON     ON     NA  
  OFF     ON     ON     ON     ON     64Kbps  
  ON     OFF     ON     ON     ON     128Kbps  
  OFF     OFF     ON     ON     ON     192Kbps  
  ON     ON     OFF     ON     ON     256Kbps  
  OFF     ON     OFF     ON     ON     320Kbps  
  ON     OFF     OFF     ON     ON     384Kbps  
  OFF     OFF     OFF     ON     ON     448Kbps  
  ON     ON     ON     OFF     ON     512Kbps  
  OFF     ON     ON     OFF     ON     576Kbps  
  ON     OFF     ON     OFF     ON     640Kbps  
  OFF     OFF     ON     OFF     ON     704Kbps  
  ON     ON     OFF     OFF     ON     768Kbps  
  OFF     ON     OFF     OFF     ON     832Kbps  
  ON     OFF     OFF     OFF     ON     896Kbps  
  OFF     OFF     OFF     OFF     ON     960Kbps  
  ON     ON     ON     ON     OFF     1024Kbps  
  OFF     ON     ON     ON     OFF     1088Kbps  
  ON     OFF     ON     ON     OFF     1152Kbps  
  OFF     OFF     ON     ON     OFF     1216Kbps  
  ON     ON     OFF     ON     OFF     1280Kbps  
  OFF     ON     OFF     ON     OFF     1344Kbps  
  ON     OFF     OFF     ON     OFF     1408Kbps  
  OFF     OFF     OFF     ON     OFF     1472Kbps  
  ON     ON     ON     OFF     OFF     1536Kbps  
  OFF     ON     ON     OFF     OFF     1600Kbps  
  ON     OFF     ON     OFF     OFF     1664Kbps  
  OFF     OFF     ON     OFF     OFF     1728Kbps  
  ON     ON     OFF     OFF     OFF     1792Kbps  
  OFF     ON     OFF     OFF     OFF     1856Kbps  
  ON     OFF     OFF     OFF     OFF     1920Kbps  
  OFF     OFF     OFF     OFF     OFF     1984Kbps  
   Note:
  1. Bandwidth setting is meaningful only when Pos.8 of SET3/SW3 is ON.
  2. In PCM30 mode, the max number of valid timeslot is 30, and the max valid bandwidth is 1920Kbps.
 
Loop back test and remote bandwidth control
   Local loop back test
  1. Set all setting switches at factory default position.
  2. Connect a coaxial cable between out and in plug of E1 port.
  3. Connected F4-56's V.35 port to a tester or router as the picture below.
  4. Run the test command of the V.35 tester or let the router check the V.35 port.
  5. If the test succeeds, all red LEDs on F4-56 should turn off. V.35 tester will report no error condition; router should see the port is UP.

    Remote loop back test
  1. Set both side in framed mode.
  2. Set local side in internal OSC clock mode, remote side in Recovery from E1 clock mode.
  3. Set Local side in master mode, remote side in slave mode, see table 4 for detail.
  4. Set Local side in remote loop back mode, see table 4 for detail.
  5. Connect devices as the picture below.
  6. Run the test command of V.35 tester or let the router check V.35 port.
  7. If the test succeeds, all red LEDs on F4-56 should turn off, the V.35 test should report no error, the router should see the port UP. The RLP LED of local side should turn on, the LLP LED of remote side should turn on.

    Remote bandwidth control
  1. Set both side in framed mode.
  2. Set local side in internal OSC clock mode, remote side in Recovery from E1 clock mode.
  3. Set Local side in master mode, remote side in slave mode, see table 4 for detail.
  6. Connect devices as the picture below.
  7. When bandwidth change required, change bandwidth of local side only, no need to go to remote side for setting the new bandwidth.
 
Typical application
  Description: In this topology, the Computers in the LAN can access the WAN or Internet using the device F4-56.