Curs valutar

22-May-2012

1 EURO = 4.4408 RON  
1 USD = 3.4767 RON  


 » Cablu de date UTP categoria 5, 5e, 6, cu sau fara sufa


Cablu UTP cat6 Leoni UTP-CAT6-L

Leoni - UTP-CAT6-L

Cablu UTP cat6

Cablu UTP LEONI/KERPEN CAT6, AWG23, role 305m

Alte imagini:
Cablu UTP cat6 Leoni UTP-CAT6-L

Pret vechi:
0,31 EURO fara TVA
Pret nou: 0,27 EURO
*) Pretul nu contine TVA

Disponibilitate : Sunati

Leoni/Kerpen cat.6 UTP Cable
 
Specifications
Construction:
 2. Conductor: bare copper wire, AWG 23/1
     Insulation: PE
     Twisting element: Pair
     Twisting: 4 pairs separated by a cross element plastic foil (optional)
     Outer sheat: halogen-free, flame retardant compound

Colour code: whbu/bu, whor/or, whgn/gn, whbn/bn
Colour outer sheat: yellow, RAL-1021

Fire behaviour:
Flame retardance: acc. to IEC 60332-1-2
Halogen acid gas emission: acc. to IEC 60754-1/2
Smoke density: acc. to IEC 61034-1/2
Calorific value (MJ/m): 0,65(aprox.)

Performance
better than category 6 acc. EN 50288 and IEC 61156
Bandwidth 300MHz

Applications:
Installation cable for generic cabling systems acc. ISO/IEC 11801 and EN 50173 (2. edition). Suitable for all applications of classes D up to E up to 1GbE acc. IEEE 802.3 ab, VoIP, PoE
Mechanical characteristics:
Bending radius:
during installation: 8 x overall diameter(min.)
after installation: 4 x overall (min.)
Tensile strength: 110(max.)
Crush (N/100mm): 1000
Impact (number of shocks): 10

Coupling attenuation up to 1000MHz(dB): 45 (nominal value)

Electrical characteristics at 20°:
DC resistance (Ohm/km): 75(max.)
Insulation resistance (Gohm x km): 5(min.)
Mutual capacitance (pF/m): 50 (approx.)
Transfer capacitance (e) (pF/km): 1500 (approx.)
Signal velocity (c): 0,67
Propaganda delay (ns/100m): 528 (approx.)
Skew at 100 MHz (ns/100m): 30 (approx.)
Characteristic impedance at 100MHz
(Ohm): 100±5
Test voltage Ueff(V): 1000
Operating voltage Ueff(V): 125(max.)
 
Frequency (MHz) 1 4 10 16 32.25 62.5 100 155 200 250 300
Attenuation
(dB/100m)
max. (Cat.6) 2.1 3.8 6 7.6 10.9 15.5 19.9 25.3 29.1 33 -
typical 1.8 2.7 4.7 6.6 9.5 13 17.4 22 26.6 30.4 33.1
NEXT (dB) min.(Cat.6) 66 65 59 56 52 47 44 41 40 38 -
typical 94 88 81 76 72 68 64 60 58 57 54
PS-NEXT (dB) min.(Cat.6) 64 63 57 54 50 45 42 39 38 36 -
typical 91 85 78 73 69 65 61 57 55 54 51
ACR (dB@100m) min.(Cat.6) 64 61 53 49 41 32 24 16 11 5 -
typical 92 85 76 70 62 55 46 38 31 27 20
PS-ACR (dB@100m) min.(Cat.6) 62 59 51 47 39 30 22 14 9 3 -
typical 89 82 73 67 59 52 43 35 28 24 17
EL-FEXT (dB@100m) min.(Cat.6) 66 58 50 46 40 34 30 26 24 22 -
typical 102 96 85 78 70 63 57 50 45 40 37
PS-ELFEXT (dB@100m) min.(Cat.6) 64 55 47 43 37 31 27 23 21 19 -
typical 99 93 82 75 67 60 54 47 42 37 34
RL (dB) min.(Cat.6) - 23 25 25 23.6 21.5 20.1 18.8 18 17.3 -
typical 25.4 30.3 33.9 33.6 33.7 34.4 33.5 32.2 30.5 29 27
 
Thermal characteristics:
Temperature range of fixed installation: -20° up to +60°C
Temperature range of mobile operation: 0°C up to +50°C
* Specificatiile pot fi schimbate fara preaviz